VU meter A700


for all Revox A700
-40 dB to 6 dB with 40 LEDs, pluggable
After the original VU meter with pointer instrument for the Revox A700 did not exist anymore, we immediately thought about how to replace the VU meter and what. A replica with pointer instruments too expensive. Alone the tool, priceless!
Existing LED VU meter not suitable or with 6 to 10 LEDs way too inaccurate.
We developed a VU meter with 20 LEDs per channel and a range of -40 dB to 6 dB.

The purpose of the ad is:
Replacement of analog instruments if one or both VU meters are defective.
As a result, you receive:
A Revox A700 with working VU meters in LED technology.
Description VU meter A700

20 LEDs


per channel provide a high resolution.
The display starts at -40 dB. The resolution is 20 dB better than the analog instrument.
From -4 dB to 4 dB  resolved with 1 dB steps.
6 dB and -6 dB lie on one line.
original revox-online led vu meter for revox a700
original revox-online led vu meter for revox a700

Appearance

the new level indicator was adapted to the original analogue VU meters as far as possible in terms of font size and response!
Overload indicator, Overload indication starts at 6 dB (514 nWb / m) and stays for 0.5 sec. on. Thus you will not miss even the slightest overdriving of the recording.
6 dB and -6 dB of the LED display are on one level.
The overload displays are located on the right and left center of the display, as well as the original!

pluggable


the VU meter amplifier PCB 1.067.425 is no longer required. Instead, the adapter board is equipped with the connections to the LED VU meter. The rectification, amplification and adjustment of the channels is done on the new LED VU meter board. The replacement of the LED version is no more expensive than replacing it with an original pointer instrument!
There is no soldering or other required and thus feasible for everyone!
LED vu meter is pluggable
Extension VU meter A700
Remove Revox A700 front panel from revox-online

front panel

To remove the VU meter, the lower front panel must be removed. For this purpose, all buttons of the controls are removed, two black and 2 aluminum screws solve the control bar.

rear panels


The back wall must be removed. For this purpose, 8 Phillips screws are loosened then tilt the rear wall slightly forward and remove it carefully (do not damage the power cord and socket area).
Set the back panels aside. The plastic tray dissolves very quickly from the aluminum rear panels. Here special care is required.

WATCH OUT! Disconnect the mains plug before opening!
Remove Revox A700 rear panels from revox-online
Revox A700 VU meter amplifier revox-online

VU meter amplifier

The PCB of the VU meter amplifier (1067.425) is connected to the Revox A700 input amplifier board with just a single screw. After removing the screw, the board can be removed from the connector J7. Now release the plug connection of the VU meter (J8).

VU meter


The VU-Meter of the Revox A700 is mounted on the rear shield plate with spring-mounted two screws.
After loosening the two red marked screws, the VU-Meter can be pulled forward.
Remove Revox A700 VU meter, revox-online
Revox A700 VU-Meter shield plate  revox-online

shield plate

The shield plate is attached to the chassis with three screws. The screws are replaced by the supplied spacers. The shield plate must be mounted from the rear of the chassis.
Single LED VU meter

Connectors


Insert the plug connector, the adapter plate of the LED VU meter of the Revox A700, past the shielding plate and back into the device
connector print VU-Meter A700  revox-online
Revox A700 connector  J7 revox-online

Connect VU meters

Plug the connector of the LED-VU meter into the socket J7 of the Revox A700. The plug is coded. Thus an accidental wrong plugging is not possible!

Mount PCB

Place the PCB of the VU meter on the three standoffs and fix it with the 3 screws M3 x 6. The upper screw (marked red) receives a fan disc to ensure good contact with the mass. The two lower screws (blue) each receive a washer.
mount VU-Meter A700 pcb revox-online
Revox A700 plexiglas revox-online

acrylic


Glue the new acrylic glass into the front panel of the Revox A700. The overlay is about 2 mm wide, which is enough to stick the glass in place.

Now the Revox A700 can be reassembled in reverse order.